Search
- WHAT'S NEW PRODUCT
- (New Products)
- September 30, 2009, ... positioning within 0.1 micron, reduced dot gain, and reduced print overpressure. A new generation carbon fiber doctor blade offers increased efficiency and higher speed from company's closed chamber design. ...
- WHAT'S NEW PRODUCTS: Carton & Bo
- (Carton Box Main)
- September 30, 2009, ... line shaft flexo presses is designed for the North American folding carton and mid-to-wide web paper industries. Standard features include closed loop tension system, fault diagnosis, touchscreen control ...
- Spool Rules
- (Winding Unwinding Rewinding)
- August 31, 2009, ... In any case, the traverse position accuracy can be maintained only if it is directly linked to the rotational velocity of the winding spool. If tension is maintained through a proper closed loop tension ...
- Print 09 Preview of Exhibits
- (Print Main)
- August 16, 2009, ... color measurement and web inspection technology that provides continuous closed-loop color control and defect detection. New KeyColor Adelphi software utilizes the output of CTP to preset the ink fountain ...
- Crime Stoppers
- (Archive)
- June 30, 2009, ... often will demand a cradle-to-grave closed security chain across the whole production and logistics process — even involving press systems integration. The options include special functional features ...
- Stress & Strain
- (Archive)
- May 31, 2009, ... zone has closed-loop tension control, in which tension is constantly corrected in response to load cell roller or dancer roller feedback, then it's easy to understand how your average slitting tension is ...
- WEB EXCLUSIVE: Tension Control: Dancer Systems Defined
- (Archive)
- April 15, 2009, A well-built, well-installed dancer working with a proper control can provide a flexible closed loop means of controlling tension in both unwind and rewind applications. One of the challenges in working ...
- Conserve Energy
- (Archive)
- January 31, 2009, ... run in a closed-loop mode, eliminating operator intervention. For solvent-based drying systems, this same concept of exhaust volume reduction can be achieved by substituting LEL (Lower Explosive Limit) ...
- Tension Control
- (Tension)
- November 30, 2008, Controller Offers Ethernet Connection Designed for precise closed loop tension control, the Spyder is capable of controlling web tension in unwind, rewind, Controller Offers Ethernet Connection Designed ...
- Who's Driving This Nip
- (Web Lines)
- November 30, 2008, ... and polyester film, this is a massive speed change and potential source of a tension upset or induced web-roller slip. If the driven rubber roller is in closed loop tension control, then this small percent ...
- Getting Carded: Card Making comes of age for Converters
- (Offset)
- October 31, 2008, ... The HCP-A100 laminator processes 9,000 cards/hr. It features programmable settings for pressure and temperature control. The closed-loop system reduces material cassette loading and transfer time. Graphics ...
- Heidelberg Speedmaster XL Perfector to Debut at Graph Expo 2008
- (News | New Products)
- October 20, 2008, ... Inpress Control, which is said to provide the fastest registration and closed loop color control available. Heidelberg also will demonstrate Prinect Color Management on the XL 105-P using Image Control, ...
- Narrow Web & Label Products
- (Narrow Web)
- September 30, 2008, ... 305 Press Is Shaftless, Flexible The updated XP5000 press is shaftless and offers a robust design for around-the-clock operation. Advanced closed loop auto-registration and tension control systems ...
- New Product Digest
- (New Products)
- August 31, 2008, ... on the material surface downstream of the ionizer. Offers closed loop feedback communications with IQ power supply to enhance the neutralizing efficiency of the system. Also features a communication module. ...
- What's New Product
- (New Products)
- June 30, 2008, ... uses ambient air temperature to cool fluid in a closed loop system that does not require make-up water or expensive chemical treatments. System is available with cooling capacities to 140 tons and flow ...
- Static Control System Ionizes Air, Monitors Web
- (News Eclips)
- June 15, 2008, ... An included web monitoring module identifies and displays any residual electrostatic charge on the material surface downstream of the ionizer, offering closed-loop feedback communication with the IQ power ...
- What's New Product
- (Magazine)
- March 31, 2008, ... on the web is monitored. GEW | +44 (0) 1737 824 500 | www.gewuv.com PFFC-ASAP 419 Get Precision Control Closed loop tension controller provides precision control over unwinding and rewinding in ...
- Correction
- (News Clips Archive)
- February 29, 2008, On p39 of the January 2008 issue of PFFC, FMS was identified as a German-based manufacturer of closed-loop control systems for web tension and web guiding On p39 of the January 2008 issue of PFFC, FMS ...
- Packaging Press Is Online
- (Offset)
- February 29, 2008, ... tried and true, and their reputation is second to none.” The press features KBA's Logotronic system that guarantees multi-system digital data communication. A closed-loop Densitronic S scanning spectrodensitometer ...
- Property Control
- (Coating/Laminating)
- January 31, 2008, ... up a small feed system and running in a closed loop. Monitoring pressure and visual examination will indicate stability. These results from solution stability measurements can be used to reformulate for ...